Hotrunner System Solutions

Select your language:
Suchwort:

Perfect gating points, minimum cavity spacing

This new method for direct gating in confined spaces uses the body of a HPS III-MH nozzle for side gating. The melt is fed laterally but the gate is positioned in demoulding direction (0°). The technology allows a minimum distance between cavities of only 6 mm and is ideally suitable for the multi point gating of medical parts or overmoulding applications in the electronical industry.  Furthermore, applications which require a gating point on a horizontal surface close to vertical walls, e.g. onto flanges of syringes and analysis tubes, can be realised. 

Product features:

  • Available in linear or radial version
  • 6 mm minimum distance between cavities
  • Synchronous plate actuation, all valve pins open and close simultaneously
  • Positioning of gating point very close to vertical part contours

Further information

HPS III-MH product brochure

Download PDF


Medical hotrunner solutions

Download PDF


Technical data

To download section